Selection of Air Valve Size

The Air Valves size can be selected 1/5 of the diameter of the main pipe for quick sizing as a thump rule.

The recommended Air Valves sizes according to pipe diameter is given below:

Pipe Diameter MM 80 - 250 300 - 400 450 - 550 600 - 1200 1250 - 2400 Above 2400
Air Valve Diameter. MM 50 - 80 80 - 100 100 - 150 150 - 200 200 - 250 250 - 300

The flow capacity of Air Valve should be at least one to one and half times of the filling rate of water in the pipe line. The flow capacity of Air Valve varies from manufacturer to manufacturer.

The flow capacity of Air Valve is calculated as below :

Qa = Ao*Co*(2*Diff.P)^0.5

Where Qa – Air Flow Capacity in Cubic meter per hour.
Ao – Orifice Area in Sq.mm. Refer Table.1.
Co – Coefficient of orifice. Refer Table.1.
Diff.P – Differential Pressure across the Air Valve in Kg. Per Sq.cm.

Table.1.
Air Valve Size in mm 50 80 100 150 200
Area of orifice (Ao) in Sq. mm. 615 1385 2641 13678 13678
Coefficient of orifice (Co) 0.85 0.85 0.85 0.85 1.35

Table.2.

Air Valve Size
in mm

Air Flow Rate (Qa) in Cub. Meter Per Hour
Differential pressure (Diff.P) Kg. Per Sq. Cm.
0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1
50 662 619 573 523 468 405 331 234
80 1489 1393 1289 1177 1053 912 744 526
100 2839 2656 2459 2245 2008 1739 1420 1004
150 14706 13756 12736 11626 10399 9006 7353 5199
200 23357 21848 20227 18465 16516 14303 11678 8258

If there are no other constraints, use maximum differential pressure of 0.35 Kg/Sq.Cm (5 PSI) for sizing to avoid excessive noise and other nuisances.

It is recommended to install Big Orifice Kinetic Air Valve / Tamper Proof Air Valve along with Small Orifice Automatic Air Valve at All Peaks, All points where there is change in gradient and Every 1500 Feet on low gradient long pipe lines. It is also recommended to install Small Orifice Automatic Air Valve at Every 500 Feet.

If the desired capacity cannot be achieved with a single Air Valve the valves can be placed in clusters – up to four air valves – on a single vent pipe from the main pipe.

Registered office at:
1404, Elitis, Lodha Aurum Chs. Ltd.,
Kanjurmarg (E), Mumbai - 400 042
Mobile: 9322593122 / 9821466441
e-mail : amflow@hotmail.com
Web site : www.amflowtechnologies.com

Factory at:
Unit No.1, Dharam Raj Industrial Estate,
Descent Soap Compound, Lake Road,
Bhandup (W), Mumbai 400 078.
Mobile: 9322593122 / 9821466441
An ISO 9001 certified company
 
   
  © 2007. Am Flow Technologies. All rights reserved.